The 2086 door system is a part of our Thermo 86 systems and is based on a strong and stable construction with 86 mm deep profiles. These are basic insulated with 42 mm glass fibre reinforced polyamide strips and filled with specially developed insulating rods SAPA Thermo N9 for optimal energy performance. The system offers very good air and rain tightness. Door leaf profiles are available for narrow and module locks as well as with anti-finger trap. Rebate for glass and infill panels 22-56 (64) mm.
2086 Plus is based on Door 2086 and retains all of its core features, but in a slightly smaller format (maximum door leaf height 2500 mm). A different threshold design improves sealing, allowing the door to meet class 2 air tightness and class 4A water tightness. For optimal energy performance, the door can be equipped with the same insulation bars, SAPA Thermo N9, as used in Door 2086 SX.
2086 Extreme is based on Door 2086 and retains all of its core features. An optimized threshold design combined with 3-point locking improves sealing, allowing the door to meet the highest requirements: class 4 air tightness and class 9A water tightness. The door can be configured as a single-leaf door with a maximum door leaf height of 2500 mm. For optimal energy performance, the door can be equipped with the same insulation bars, SAPA Thermo N9, as used in Door 2086 SX.
This door which provides safe operation and long service life is perfectly suitable for busy public environments requiring high thermal insulation and air and rain performance.
Performance
2086 Standard | 2086 Plus | 2086 Extreme | |
Thermal performance | Ud-value: as low as 1,1 W/m²K for double door (Standard). Ud-value: as low as 0,8 W/m²K for double door (SX) | Ud-value: as low as 1,1 W/m²K for double door (Standard). Ud-value: as low as 0,8 W/m²K for double door (SX) | Ud-value: as low as 1,1 W/m²K for double door (Standard). Ud-value: as low as 0,8 W/m²K for double door (SX) |
Air permeability | n/a | Up to class 2 according to EN 12207 | Up to class 4 according to EN 12207 |
Water thightness | n/a | Up to class 4A according to EN 12208 | Up to class 9A according to EN 12208 |
Wind resistance | n/a | Up to C2 according to EN 12210 | Up to C3 according to EN 12210 |