Plaisance 50

Interior partitioning system

Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a 50 mm building depth. The system offers a wide range of inward and outward opening possibilities, available at a very good price-quality level. Plaisance 50 is a comprehensive solution for new build or refurbishment projects. 

Plaisance 50 Description

  • Plaisance 50 is a non-thermally insulated system with a solution for all standard applications.
  • The system accommodates glazing of 4 to 35,5 mm. For plates, the infill thickness can start from 2 mm.
  • The combination of multipoint locking, safety glass and special hardware ensures high resistance against forced entry. Internal tubular glazing beads prevent unclipping from the outside.
  • Forced entry resistance: ENV 1627 - 1630 class 2
  • A wide range of locking and non-locking handles are integrated in the system.
  • Inward opening vents connect to a solid central gasket for a better acoustic insulation. 
  • All standard shades and ventilation systems can easily be integrated in Plaisance 50.
  • It is compatible within its profile and hardware range, as well as with other Sapa Building System products, e.g. curtain wall and conservatory systems.
  • Specially designed gaskets, a large decompression chamber and internal drainage to assure perfect weather resistance.
  • Effective water evacuation via punched drain holes.
  • Special finishing profiles provide additional building drainage.The acoustic performance is greatly enhanced with multiple gaskets.

 

 

Plaisance 50 Designs

  • Plaisance 50 is rounded (Softline) on the inside and straight or bent (Futuro) on the outside.
  • Design glazing beads add extra finish
  • Hidden drainage frames are an alternative for drainage caps.
  • A comprehensive range of supplementary finishing profiles allows the fenestration to be perfectly integrated into the building. 
  • Vent, frame and transom profiles are available in several dimensions and meet the requirements regarding stability and design.
  • Wide choice of hinges, handles and hardware.
Design glazing beads
Plaisance 50 Futuro
Plaisance 50 Softline
Plaisance 50 Outward Opening

Characteristics

Dimensions
Minimum sightline fixed frame 50 mm
Minimum sightline window with inward opening vent 89 mm
Min. sightline window with outward opening vent (top hung) 95 mm
Minimum sightline transom 72 mm
Building depth frame 50 mm
Building depth vent 60 mm
Maximum window (one single vent - W x H) 1100 x 2100 mm
 
Glazing
Rebate height 22 mm
Infill thickness fixed frame and vent (inward opening) 2 - 35,5 mm
Infill thickness vent (outward opening) 2 - 45,5 mm
Glazing method dry glazing with EPDM gaskets or silicon

Applications

fixed window

turning window inwards opening

tilt-turn window inwards opening

turning window outwards opening

horizontally pivoting window

Vertically pivoting window

Combination of inward turning window and inward tilting window above

combination of inward tilt-turn window with fixed window above

Combination of inward opening window, fixed window and inward tilting windows

combination of inwards tilt-turn window with fixed windows

double inwards opening window; one turning vent, one tilt-turn vent

double window with one tilt-turn, inwards opening vent

Performances

Air Tightness

4 - 600 Pa

Air Tightness

Air tightness refers to the amount of air that will travel through a window or door system in its closed position, both under positive and negative pressure.

Norm

EN 12207

Water Tightness

E750 - 750 Pa

Water Tightness

The test applies specified amounts of water spray to the outside face of the window (combination) while incrementally increasing the air pressure. The result defines the test pressure, time and position of any water infiltration.

Norm

EN 12208

Wind Resistance

A5 - 2000 Pa, security 3000 Pa

Wind Resistance

The test applies a series of positive and negative test air pressures. Measurements and inspections are made to asses relative frontal deflection and resistance to damage from wind loads.

Norm

EN 12210

Acoustic Insulation

Rw (C;Ctr) = 40 (-2;-4) dB (44.2/12/10)

Acoustic Insulation

defines single-number quantities for airborne sound insulation in buildings and of window (combinations)

Norm

EN ISO 707 / EN ISO 140

Forced Entry Resistance

RC2

Forced Entry Resistance

Description for Forced Entry Resistance

Norm

ENV 1627 - 1630

Technical Sections

pdf
Download 117 KB
pdf
Download 128 KB
pdf
Download 143 KB
pdf
Download 142 KB
pdf
Download 118 KB

Documentation

PB_Plaisance50_BRen_102015.pdf PB_Plaisance50_BRen_102015.pdf
PB_Plaisance50_BRen_102015.pdf
Download 500 KB

Product overview

Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a 50 mm building depth. The system offers a wide range of inward and outward opening possibilities, available at a very good price-quality level. Plaisance 50 is a comprehensive solution for new build or refurbishment projects. 

SAPA BUILDING SYSTEMS -
Please choose your language