Sapa Door 2074/ Glazed Elements 3074 class RC2, RC3

Please note:  all products in the 74 systems expire December 31, 2019 and are replaced by the corresponding product in the 86 systems.

With our 2074 Door system we can offer the market glazed anti-burglar doors that have as elegant appearance as normal doors. The difference is that anti-burglar doors are complemented with glazing units, locks and infill panels, which meet the anti-burglar protection requirements for the applicable class. The doors can be made as either inward or outward opening, using narrow or modular profiles. The combination of glazing units and infill panels can be adapted to the customer’s requirements. The classification of anti-burglar doors is done according to EN 1627.

Elevations & Details

A2074-1129 212223246
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1130 21222467
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1131 1221222324356
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1132 122122243667
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1133 12356
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1135 212223246
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1136 21222467
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1137 1221222324356
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1138 122122243667
Save this elevation as: dwg / dxf
Click on number to view the details
A2074-1139 12356
Save this elevation as: dwg / dxf
Click on number to view the details

Drawing texts

The texts are intended to help the specifiers to define which systems, fittings, glazing units, surface treatment alternatives and functions are required. The licensed fabricators later use them during the production of the finished products.

Download the text as .dwg
Download the text as .pdf

Clear dimension

Doors and entries should be designed with enough space (clear dimension) for person traffic and to allow passage in a wheel chair. Applicable standards and requirements should be taken into account.

Rebate door

= Clear dimension
= Frame outside dimension
= Wall opening

D with universal hinge139 mm 
D with lap but hinge133 mm
67 mm or 70 mm with replaceable rebate profiles

Glazing

The glazing unit type and thickness shall meet the requirements for the applicable protection class.

For more information please contact our Architect Support.

Infill panels

Certain parts of the elements can or must be filled with infill panels. The infill panels shall meet the requirements for the applicable protection class. It is necessary to specify which type of surface layer the element shall have, e.g. aluminium sheet or stainless steel sheet.

For more information please contact our Architect Support.

Fittings

Consistent choice of materials. The door system, hinges and pull handles of aluminium give a uniform appearance. The door closing device has the same colour as the frame. Clear anodising ensures good resistance and preserves the feeling of metal, one of stability and long-term thinking.

Hinges

Bladgångjärn treblad
Lap butt hinge,
3-segment.
Art nr: Sapa 14 046
For anit-squeeze
back edge:
Art. no.: Sapa 14 041
Lap butt hinge.
Doors 2050
Art. no: Sapa 14 072

 

Pull handles

Handtag svängt
Bent pull handle
with hidden mounting harmonises with
the door leaf.
Height 300 mm, Ø 30 mm.
Art. no.: Sapa 14 128
Triangular pull handle
with hidden mounting harmonises with
the door leaf.
Height 300 mm, Ø 30 mm.
Art. no.: Sapa 14 129
Semi-circular pull handle
with hidden mounting harmonises with
the door leaf.
Height 300 mm, Ø 30 mm.
Art. no.: Sapa 14 130

Handles

Handtag svängt
Handle for modular
profile door.
Width 141 mm,
Ø 17,5 mm.
Art. no.: Sapa 14 131
Handle for modular
profile door.
Width 137 mm,
Ø 21 mm.
Art. no.: Sapa 14 132
Handle for modular
profile door.
Width138 mm.
Art. no.: Sapa 14 133

 

Door closing devices

Door closing device with arm.
According to supplier.

Sliding rail door closing device.
According to supplier.

Built-in door closing device.
According to supplier.
Automatic door opening device.
According to supplier.

Threshold

Anti-burglar doors are always made with a threshold. The connection with the door leaf shall be made with a rebate. Applicable standards and requirements should be taken into account.

Threshold. See Elevations and details in the right hand menu.

Fixing principles

Door elements must be fixed to a ridged and suitable wall structure. The choice of fixing method depends on the wall type. The number and location of fixing points depends on the size of the element.

Examples:

     
Fixing of frame with adjustable frame bushing   Fixing of frame with bolt and
welded plate
   

 

 

Product overview

Please note:  all products in the 74 systems expire December 31, 2019 and are replaced by the corresponding product in the 86 systems.

With our 2074 Door system we can offer the market glazed anti-burglar doors that have as elegant appearance as normal doors. The difference is that anti-burglar doors are complemented with glazing units, locks and infill panels, which meet the anti-burglar protection requirements for the applicable class. The doors can be made as either inward or outward opening, using narrow or modular profiles. The combination of glazing units and infill panels can be adapted to the customer’s requirements. The classification of anti-burglar doors is done according to EN 1627.